What was found
TYS - DURING A SCHEDULED 1C INSPECTION, RIGHT OMEGA BEAM AT FRAME 20 BETWEEN STRINGERS 21R AND 20R WAS FOUND TO HAVE CORROSION. MAINTENANCE BLENDED OMEGA BEAM, PERFORMED DYE PENETRANT INSPECTION. ALODINED AND PRIMED IAW EMB REF GST 0409/01, EMB 145 NDI MM 53-00-00 AND CMP 51-21-03 AND 51-21-04. BLENDING PROCEDURES WERE SATISFACTORY, AIRCRAFT WILL BE RELEASED FOR SERVICE UPON COMPLETION OF C-CHECK. (M)