What was found
TYS - DURING A SCHEDULED 1C INSPECTION, A GOUGE WAS FOUND IN FRAME 70 BETWEEN BLEED LINE AND CARGO FLOOR. MAINTENANCE BLENDED GOUGE, DYE PENETRANT INSPECTED, ALODINED AND PRIMED AREA IAW EMB REF GST 0427/01, 145-NDI MANUAL 53-31-00, CMP 51-21-03 AND 51-21-05. PROCEDURES WERE SATISFACTORY. AIRCRAFT WILL BE RELEASED FOR SERVICE UPON COMPLETION OF C-CHECK. (M)