TYS - DURING A SCHEDULED 1C INSPECTION, THE APU FIRE LOOP WAS FOUND CHAFED. MAINTENANCE REMVOED AND REPLACED THE FIRE LOOP IAW EMB 145 MM 26-12-01. PROCEDURES WERE SATISFACTORY, AIRCRAFT WILL BE RELEASED FOR SERVICE UPON COMPLETION OF C-CHECK. (M)