As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
TYS DURING A SCHEDULED INSPECTION, THE LEFT AILERON CENTER INBOARD ATTACH FITTING WAS FOUND GOUGED. MAINTENANCE BLENDED OUT THE DAMAGED AREA, PERFORMED DYE-PENETRANT INSPECTION, ALODINED, PRIMED AND PAINTED THE AILERON FITTING IAW-EMB-145-GST-3059/01. THE REPAIR WAS SATISFACTORY AND THE AIRCRAFT WILL BE RELEASED UPON COMPLETION OF INSPECTION.