What was found
TYS DURING A SCHEDULED 1-C INSPECTION CORROSION WAS FOUND UNDER THE SERVICE DOOR SILL AND SCREW HOLES. MAINTENANCE REMOVED AND REPLACED ONE NUT PLATE, CLEAN THE CORROSION, REFINISH THE AREA IAW EMB 135/145 SRM 51-40-02 AND CPM 51-17-04--51-21-07, ALL WORK WAS ACCOMPLISH AND WILL BE RELEASED UPON COMPLETION OF ALL MAINTENANCE.