What was found
TYS DURING A SCHEDULED INSPECTION THE FLOOR SUPPORT ANGLES LOCATED BELOW THE THRESHOLD STRIP AT THE MAIN ENTRY DOOR WAS FOUND TO HAVE SEVERAL AREAS OF CORROSION. MAINTENANCE ACCOMPLISHED A BLEND-OUT REPAIR IAW EMB-135 SRM 51-20-03, 51-40-02 AND CPM 51-21-04,05,06. THE REPAIR WAS FOUND TO BE SATISFACTORY. THE AIRCRAFT WILL BE RELEASED UPON COMPLETION OF INSPECTION.