What was found
TYS DURING A SCHEDULED 1-C INSPECTION CORROSION WAS FOUND AT THE LEFT OMEGA BEAM. MAINTENANCE CLEAN INSPECTED AND OVERSIZE ONE RIVET IAW EMB 135/145 SRM 51-10-02 AND 51-40-02. WILL BE RELEASED UPON COMPLETION OF THE 1-C INSPECTION.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TYS DURING A SCHEDULED 1-C INSPECTION CORROSION WAS FOUND AT THE LEFT OMEGA BEAM. MAINTENANCE CLEAN INSPECTED AND OVERSIZE ONE RIVET IAW EMB 135/145 SRM 51-10-02 AND 51-40-02. WILL BE RELEASED UPON COMPLETION OF THE 1-C INSPECTION.