As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
TYS DURING A SCHEDULED 1-C INSPECTION CORROSION WAS DETECTED ON CENTER SUPPORT RAMP NEXT TO THE CARBON FIBER CROSSBEAM. MAINTENANCE REMOVED AND REPLACED THE RAMP ANGLE AND REINSTALLED THE CARBON FIBER CROSSBEAM IAW EMB 135/145 SRM 51-40-02. ALL WORK WAS ACCOMPLISHED AND WILL BE RELEASED UPON COMPLETION OF THE 1-C INSPECTION.