As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SHV- DURING C-CK INSPECTION, THE RIGHT HAND INBOARD FLOORBEAM AT FRAME 20 WAS FOUND TO BE CORRODED. MAINTENANCE REMOVED AND REPLACED THE AFFECTED SECTION OF FLOORBEAM IAW EMB-145 SRM 51-40-02, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.