What was found
SHV- DURING C-CHECK INSPECTION, CENTER FLOORBEAM STRAP FOUND TO HAVE NUT PLATES CORRODED AND SURFACE CORROSION FROM FRAME 15 TO 17. MAINTENANCE REMOVED DAMAGED AREA, FABRICATED REPAIR PARTS IAW EMB 145 SRM 53-21-10 PG 210 ITEM 4 FIG 203, INSTALLED REPAIR PARTS IAW EMB 145 SRM 53-21-10 AND SRM 51-40-02. AIRCRAFT WAS APPROVED TO RETURN TO SERVICE.