What was found
TYS, During a scheduled 1C inspection, the right inboard flap track was found worn by roolers at normal flap degree stops. Maintenance blended the worn areas, performed dye penetrant inspection (no defects noted, I/A/W-EMB-GST-0355/02, repair procedures are satisfactory and aircraft will be released upon complection of inspection.