As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
TYS DURING A SCHEDULED 1-C INSPECTION THE RAMP SUPPORT ON THE CENTER OMEGA BEAM BETWEEN FR'S 19 AND 20 HAS A AREA OF CORROSION. MAINTENANCE REMOVED AND REPLACED THE RAMP SUPPORT IAW EMB 135/145 SRM 51-40-02. WORK WAS SATISFACTORY AND WILL BE RELEASED UPON COMPLETION OF INSPECTION.