What was found
TYS DURING A SCHEDULED 1C/2C INSPECTION THE HORIZ. STAB HINGE PIN LOCKING BRACKETS ON THE LT. AND RT. SIDE HAD WEAR STEPS IN THEM. MAINT. BLENDED THE WEAR STRIPS,PERFORMED NDT INSPECTION,ALLODINED,PRIMED AND PAINTED IAW WITH GST#1391/02-EMB 135/145 CPM 51-21-04,05.06. ALL WORK WAS ACCOMPLISH AND WILL BE REL. UPON COMPLETION OF ALL WORK.