What was found
TYS DURING A SCHEDULED 1C/2C INSPECTION THE TOP CAP AT FRAME 17-18 WAS CORRODED. MAINTENANCE REMOVED THE CORROSION AND BLENDED THE AREA, REPLACED THREE RIVET'S, ALODINE, PRIMED AND PAINTED IAW EMB 145 SRM 51-40-02, 51-10-02, 51-21-04-05-06. ALL WORK WAS ACCOMPLISHED AND WILL BE RELEASED UPON COMPLETION OF ALL WORK.