What was found
TYS DURING A SCHEDULED 1C/2C INSPECTION,THE PAX DOOR HAD TWO DENTS IN THE MIDDLE OF THE DOOR. A GST WAS USED TO MAKE THE REPAIR (GST 1906/02) WHICH STATED REMOVE PAINT, RECONTOUR THE DENTED AREA, PERFORM A DYE-PENETRANT INSPECTION, NO CRACK WAS FOUND. AREA WAS ALODINED, PRIMED AND PAINTED IAW WITH THE GST AND EMB 135/145 CPM 51-21-04-05-06. AIRCRAFT WILL BE RELEASED UPON COMPLETION OF ALL 1C/2C INSPECTION.