What was found
TYS DURING A 1C/2C INSPECTION,STRINGER 19R AT STA.17727.0 WAS FOUND CHAFED. MAINTENANCE MEASURED AREA(L=.4670" XW=.1495" X D=.016") FOUND TO BE WITHIN LIMITS,BLENDED DYE PENTRANT INSPECTION,ALODINE,PRIMED AND RESORED TOPCOAT IAW EMB.135/145 SRM 53-24-02 AND CPM 51-21-04-05-06.ALL WORK WAS ACCOMPLISH AND WILL BE REL. UPON COMPLETION OF ALL WORK.