What was found
TYS DURING A SCHEDULED ROUTINE CHECK THE LH INBD FLAP TRAILING EDGE,UPPER SURFACE AERODYNAMIC FILLER WAS FOUND CRAZING AND CRACKING. THE AREA WAS 18"L X8.25"W, WITH A AREA WITHIN THAT THAT WAS 1.25" X 1.5" THAT THE FILLER WAS MISSING. MAINT. REQUESTED A GST FOR THE FLAP AND WAS ISSUED GST-2155/02 WHICH ALLOWED MAINTENANCE TO PUT SPEED TAPE OVER THE AREA AND DO A GVI EVERY ROUTINE CHECK FOR 500FC IN THAT IT WILL BE REPAIRED OR REPLACED.ALL WAS C/W AND PUT ON DMI.