What was found
TYS DURING A SCHEDULED 1-C INSPECTION, A CHAFE MARK WAS FOUND ON FRAME 70 NEXT TO THE BLEED AIR DUCT. BLENDED OUT THE AREA, PERFORM A DYE INSPECTION, ALODINED AND PAINTED. NO DEFECTS WERE FOUND AND WILL BE RELEASED UPON COMPLETION OF ALL WORK.