As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
TYS DURING A SCHEDULED 2-C INSPECTION THE SERVICE DOOR FORWARD SILL WAS FOUND CORRODED. MAINTENANCE R/R THE SERVICE FORWARD SEAL IAW EMB 145 SRM 52-10-02 AND EMB 145 CPM 51-21-05. ALL WORK WAS ACCOMPLISHED AND WILL BE REL. UPON COMPLETION OF ALL WORK.