What was found
DURING A SCHEDULED 2-C INSPECTION, MAINTENANCE FOUND A DENT IN NR 1 RUDDER, RT SIDE BETWEEN RIB 2890.0 AND 2601.0. THE AREA WAS CUT OUT AND A EXTERNAL DOUBLER WAS FABRICATED. DRILLED,ALODINED,PRIMED AND PAINTED AND INSTALL THE DOUBLER. ALL WORK WAS ACCOMPLISHED IAW GST 3254/02;EMB 145 SRM 51-40-02'03 CPM 5121-04-05-06. A/C WILL BE REL. UPON COMPLETION OF ALL WORK.