As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CREW REPORTED SMELL IN FORWARD CABIN AREA, INSPECTED FORWARD CABIN AREA AND FOUND FLIGHT ATTENDANTS EMERGENCY FLASHLIGHT CHARGER OVERHEATING. PLACED FORWARD EMERGENCY FLASHLIGHT AND HOLDER ON MEL 25-60-05 CONTROL 037554 CATEGORY-C (CIRCUIT BREAKER FOR FLIGHT ATTENDANTS FLASHLIGHT PULLED). MAINTENANCE REMOVED AND REPLACED FLIGHT ATTENDANTS EMERGENCY FLASHLIGHT UNIT. OPS CHECKED GOOD IAW EMB145 AMM 33-50-16. AIRCRAFT RETURNED TO SERVICE.