As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SHV DURING C CHECK THE CENTER OMEGA BEAM WAS FOUND TO HAVE CORROSION ON THE LOWER FLANGE BETWEEN FRAMES 24-25. MAINTENANCE REMOVED DAMAGE AND REPAIRED AFFECTED OMEGA BEAM IAW 145 SRM 53-22-10. THE AIRCRAFT WAS APPROVED TO RETURN TO SERVICE.