SHV DURING C-CHECK THE RAMP ANGLE ON CENTER OMEGA BEAM BETWEEN FRAMES 19 AND 20 WAS FOUND TO HAVE CORROSION. MAINTENANCE REMOVED DAMAGE AND REPLACED AFFECTED RAMP ANGLE IAW EMB 145 SRM 53-21-10. THE AIRCRAFT WAS APPROVED TO RETURN TO SERVICE.