As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING A SCHEDULED 2-C INSPECTION THE RAMP ANGLE AT THE FWD CENTER OMEGA BEAM WAS CORRODED. MAINTENANCE REMOVED AND REPLACED THE RAMP ANGLE IAW 135/145 SRM 51-40-02. ALL WORK WAS ACCOMPLISH AND WILL BE RELEASED UPON COMPLETION OF ALL WORK.