What was found
DURING A SCHEDULED 2-C INSPECTION THE CARGO DOOR SILL WAS FOUND CORROCDED. MAINTENANCE REMOVED DOOR, REMOVED THE COVER SILL, LOCATED, DRILL NEW DOOR SILL, INSTALLED DOOR PROTECTIVE STRIPS AND INSTALLED DOOR. PRESSURE CHECK WAS GOOD IAW 135/145 SRM 53-40-02. ALL WORK WAS ACCOMPLISHED AND WILL BE RELEASED UPON COMPLETION OF ALL WORK.