What was found
TYS DURING A SCHEDULED 2C INSPECTION THE LT FLOOR SILL IN THE LAV AREA HAD SOME CORROSION. MAINT REMOVED AND REPLACED THE LT FLOOR SILL IN THE LAV, REMOVED AND REPLACED LT CARBON FIBER IAW EMB 135/145 SRM 51-40-02. ALL WORK WAS ACCOMPLISHED AND WILL BE RELEASED UPON COMPLETION OF ALL WORK.