As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING A SCHEDULED INSPECTION CORROSION WAS FOUND ON THE GALLEY FLOOR SUPPORT CENTER OMEGA TOP CAP. MAINTENANCE REMOVED AND REPLACED THE TOP CAP IAW EMB SRM 41-40-02, THE REPAIR WAS SATISFACTORY. THE AIRCRAFT WILL BE RELEASED UPON COMPLETION OF INSPECTION.