As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
TYS DURING A SCHEDULED 1C INSPECTION DAMAGE WAS FOUND ON STR 19L AND 19R AT FR 53. MAINT BLENDED OUT DAMAGE, PERFORMED A NDI TEST, NO CRACK FOUND. FABBED A EXTERNAL DOUBLER AND SHIMS; ALODINED, PRIMED THE EXTERNAL DOUBLER. INSTALL THE FAB PARTS IAW EMB 135/145 SRM 53-21-02; CPM 51-21-04-05-06. ALL WORK WAS ACCOMPLISHED AND WILL BE RELEASED UPON COMPLETION OF ALL WORK.