What was found
SHV-DURING C-CHECK THE CENTER FLOORBEAM WAS FOUND TO BE CORRODED OUT OF LIMITS IAW SRM 53-21-10. MAINTENANCE REMOVED AND REPLACED THE AFFECTED BEAM IAW SRM 51-40-02. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SHV-DURING C-CHECK THE CENTER FLOORBEAM WAS FOUND TO BE CORRODED OUT OF LIMITS IAW SRM 53-21-10. MAINTENANCE REMOVED AND REPLACED THE AFFECTED BEAM IAW SRM 51-40-02. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.