What was found
TYS, DURING A SCHEDULED INSPECTION THE LEFT OUTBOARD FLOOR SUPPORT BETWEEN FRAMES 61 AND 64 WAS FOUND DAMAGED. MAINTENANCE REMOVED THE FLOOR SUPPORT, FABRICATED NEW PARTS, ALODINED, PRIMED AND INSTALLED IAW EMB-135/145 SRM 51-40-02/03 AND CMP-51-21-04.