As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
TYS DURING A SCHEDULED 2C INSPECTION THE SERVICE DOOR FWD SILL WAS FOUND CORRODED. MAINT BLENDED AND MEASURED AREA, FAB AND INSTALL DOUBLER IAW EMB 135/145 SRM 53-21-10. ALL WORK WAS ACCOMPLISHED AND WILL BE RELEASED UPON COMPLETION OF ALL WORK.