What was found
TYS DURING A SCHEDULED 1C INSPECTION THE LT FLOORBEAM WAS FOUND CORRODED AT FR 20. MAINT CUT OUT THE EFFECTED AREA, FAB DRILLED AND COUNTERSUNK A NEW REPAIR PART, ALODINED, PRIMED, PAINTED AND INSTALL THE NEW PART IAW EMB 135/145 SRM 53-21-10; 51-20-03-06 AND CPM 51-21-04; 05; 06, SRM 51-40-02. ALL WORK WAS ACCOMPLISHED AND WILL BE RELEASED UPON COMPLETION OF ALL WORK.