As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING A SCHEDULED 2C INSPECTION THE PAX DOOR WAS FOUND WITH 3 DENTS IN IT. DENT 1 AND DENT TWO WERE FOUND WITHIN LIMITS. ALODINED PRIMED AND PAINTED IAW EC5210-01103. DENT NR 3 WAS OUT OF LIMITS. MAINTENANCE CUT OUT AFFECTED AREA, FAB A DOUBLER AND FILLER AND INSTALLED IAW EC 5210-01104. ALODINED AND PAINTED AREA AFFECTED IAW 135/145 CPM 51-21-04; 05; 06. PRESSURE CHECKS PERFORMED AND GOOD. ALL WORK WAS ACCOMPLISHED AND WILL BE RELEASED UPON COMPLETION OF ALL WORK.