What was found
SHV - DURING C-CHECK MAINTENANCE FOUND CORROSION ON THE CENTER OMEGA BEAM AT FRAME 25-29. MAINTENANCE REPAIRED CENTER OMEGA BEAM AT FRAME 29 IAW EMB 145 SRM 53-00-10, SECTION 4, FIGURE 203, SHEET 2. INSTALLED NUT PLATES IAW EC 5320-01137. PAINTED REPAIR AREA IAW EC 5320-01140. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.