As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
IAH - FLIGHT 3096, DURING TAKEOFF THE CREW REPORTED SMOKE IN THE CABIN FOLLOWED BY BLEED 1 LEAK. THE AIRCRAFT RETURNED TO IAH WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED THE AIRCRAFT AND FOUND THE NR 1 BLEED DUCT BETWEEN FR 56 & 60 TO BE BLOWN. MAINTENANCE REMOVED AND REPLACED THE AFFECTED BLEED DUCT, OPERATIONALLY CHECKED WITH NO DEFECTS. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.