What was found
TYS DURING A 2C INSPECTION THE FWD L ANGLE IN THE CARGO DOORWAY WAS FOUND WITH CORROSION. MAINTENANCE REMOVED THE CARGO DOOR SILL AND THE CORROSION; FR 68 SHEAR CLIP, REPAIRED CARGO DOOR SILL, ALODINED, PRIMED, PAINTED AND SEALED EC 5330-01458. ALL WORK WAS ACCOMPLISHED AND WILL BE RELEASED UPON COMPLETION OF ALL WORK.