What was found
TYS - DURING A CURRENT 2C INSPECTION, A DENT BETWEEN RIB 22 AND 23 ON THE LEFT WING WAS FOUND. MAINTENANCE RECONTOURED THE DENTED AREA, PERFORMED A DYE PENETRANT INSPECTION, FOUND NO CRACKS. FABRICATED, DRILLED, ALODINED AND INSTALL TWO INTERNAL "L" SHAPED DOUBLERS. PRIMED AND PAINTED IAW EC 5710-01095;EMB 145XR CPM 51-40-02 AND CPM 51-21-05,06. ALL WORK WAS ACCOMPLISHED AND WILL BE RELEASED AT THE END OF THE 2C INSPECTION.