What was found
TYS DUE TO A GROUND DAMAGE FRAME 72 WAS DENTED AT STR 15R. MAINTENANCE PERFORMED NDU ON FR 72 AT STR 15 AND FOUND TO BE CRACKED. CUT THE FRAME BETWEEN STR 17 AND STR 18 AND PREPARED NEW PART FOR SPLICE. INSTALL NEW SPLICE. INSTALL NEW FRAME AND SPLICE IAW EMB 145 SRM 51-40-02; 52-00-04; EC 5330-01643. ALL WORK WAS ACCOMPLISHED AND WAS RELEASED AFTER LEAK AND PRESSURE CHECKS WERE GOOD.