Service difficulty report · Inverter · Emb EMB145XR

Difficulty date
May 22, 2007
Submitted
May 23, 2007
Operation
Air carrier
Aircraft
N14173
Make and model
Emb EMB145XR
Aircraft serial
14500872
Aircraft time
7,288 hours, 3,927 cycles
Part
Inverter
Part number
78241
Condition
Inoperative
Location
Emergency Lights
Stage of operation
IN
How discovered
C
Nature of condition
L
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

IAD - DURING ROUTINE MAINTENANCE, MX FOUND RIGHT OVERWING EMERGENCY LIGHT EXIT INOP. MX PROCEED WITH TROUBLESHOOTING AND FOUND INVERTER INOP. MX REMOVED AND REPLACED INVERTER AND PERFORMED OPERATIONAL CHECK SUCCESSFULLY. ACFT WAS APPROVED TO RETURN TO SERVICE.