As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RIC - DURING ROUTINE MAINTENANCE, MX FOUND NR 3 EMERGENCY FLOOR PROXIMITY LIGHT STRIP HAD THE CONNECTOR BROKEN. MX REMOVED AND REPLACED CONNECTOR PIN IAW EMB 145 AMM 20-13-12 AND WM 33-50-50. MX PERFORMED OPERATIONAL CHECK SUCCESSFULLY. ACFT WAS APPROVED TO RETURN TO SERVICE.