As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING A CURRENT 1C/5C INSPECTION CORROSION WAS FOUND ON BOTH ENDS OF A COMPOSITE CROSSMEMBER FLOOR SUPPORT AT FR PANEL 231FF. MAINTENANCE REPAIRED THE OMEGA BEAM AT THE DESIGNATED AREA IAW SRM 53-00-10.REMOVED AND REPLACED THE RAMP ANGLE IAW SRM 51-40-02. ALL WORK WAS ACCOMPLISHED AND WILL BE RELEASED AT THE END OF THE CHECK.