What was found
TYS DURING A CURRENT 1C INSPECTION, CORROSION WAS FOUND ON THE CENTER OMEGA BEAM TOPCAP AT FR 20. MAINTENANCE REMOVED AND REPLACED THE OMEGA BEAM IAW EMB 145 SRM 51-40-02. DRILL, COUNTERSUNK, ALLODINED, PRIMED AND PAINTED NEW PART IAW EMB 145 51-21-03 AND CPM 51-21-07. ALL WORK WAS ACCOMPLISHED AND WILL BE RELEASED UPON COMPLETION OF THE C-CHECK INSPECTION.