As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
TYS - DURING A CURRENT 5C INSPECTION THE LT HORIZONTAL STAB HINGE FITTING WAS FOUND MIGRATED. MAINTENANCE REMOVED THE LT STAB BUSHING, REWORKED HOUSING TO THE 2ND OVERSIZE DIAMETER AND INSTALLED THE 2ND SIZE BUSHING IAW EMB 135/145 SRM 55-10-02. ALL WORK WAS ACCOMPLISHED AND WILL BE RELEASED UPON COMPLETION OF THE 5C INSPECTION.