What was found
TYS - DURING A CURRENT 2C INSPECTION A CRACK WAS FOUND AT A RIVET AT FRAME 75, BETWEEN STR 1L AND 2L. MAINTENANCE CUT OUT THE DAMAGED AREA, FABRICATED DOUBLERS, INSTALLED FILLERS AND DOUBLERS, ALODINED, PRIMED AND PAINTED IAW EC 53330-01681. ALL WORK WAS ACCOMPLISHED AND WILL BE RELEASED AT THE END OF C-CHECK INSPECTION.