What was found
SHV - DURING C-CHECK IT WAS FOUND THAT THE CENTER OMEGA BEAM WAS CORRODED AT FRAME 20. MAINTENANCE REMOVED AND REPLACED THE AFFECTED BEAM IAW EMB 145 SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE. (S)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SHV - DURING C-CHECK IT WAS FOUND THAT THE CENTER OMEGA BEAM WAS CORRODED AT FRAME 20. MAINTENANCE REMOVED AND REPLACED THE AFFECTED BEAM IAW EMB 145 SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE. (S)