What was found
SHV - DURING C-CHECK IT WAS FOUND THAT THE LT HORIZONTAL STAB HINGE PIN FITTING WAS GOUGED. MAINTENANCE PERFORMED A REAMING PROCEDURE TO THE FIRST OVERSIZE IAW EMB 145XR SRM 55-10-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE. (S)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SHV - DURING C-CHECK IT WAS FOUND THAT THE LT HORIZONTAL STAB HINGE PIN FITTING WAS GOUGED. MAINTENANCE PERFORMED A REAMING PROCEDURE TO THE FIRST OVERSIZE IAW EMB 145XR SRM 55-10-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE. (S)