As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SHV - DURING C-CHECK IT WAS FOUND THAT THE RT HORIZONTAL STAB HINGE PIN FITTING HAD MIGRATED PLAIN BUSHINGS. MAINTENANCE PERFORMED A REAMING PROCEDURE TO THE SECOND OVERSIZE IAW EMB 145XR SRM 55-10-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE. (S)