What was found
SHV DURING C CHECK THE RT OMEGA BEAM WAS FOUND TO BE CORRODED AT FRAME 23. MX PERFORMED A DOUBLER REPAIR IAW CONTINENTAL EXPRESS EC5320-01228. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.