What was found
TYS - DURING C-CHECK INSPECTION FOUND THE NR 2 ENG AIR INTAKE MOUNTING FLANGE BOLT HOLES CORRODED. COMPLETED REPAIRS FOR 4 HOLES AT .300 INCH AND 11 HOLES FOR BUSHING INSTALLATION IAW EC 5420-01158. A/C STILL IN C-CHECK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TYS - DURING C-CHECK INSPECTION FOUND THE NR 2 ENG AIR INTAKE MOUNTING FLANGE BOLT HOLES CORRODED. COMPLETED REPAIRS FOR 4 HOLES AT .300 INCH AND 11 HOLES FOR BUSHING INSTALLATION IAW EC 5420-01158. A/C STILL IN C-CHECK.