What was found
TYS - DURING ROUTINE MX THE MAIN DOOR EMERGENCY LIGHT WAS FOUND INOP. THE MAIN DOOR EMERGENCY LIGHT WAS REMOVED AND REPLACED IAW EMB 145 AMM 33-50-06 AND OPS CHECKED GOOD. A/C WAS RELEASED TO SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TYS - DURING ROUTINE MX THE MAIN DOOR EMERGENCY LIGHT WAS FOUND INOP. THE MAIN DOOR EMERGENCY LIGHT WAS REMOVED AND REPLACED IAW EMB 145 AMM 33-50-06 AND OPS CHECKED GOOD. A/C WAS RELEASED TO SERVICE.